Skip to content
Asia NDE

Heat Exchanger Tube Inspection Equipment

Heat exchanger tube inspection checks condenser, heat exchanger and fin fan tubes from the inside for wall thinning, pitting and cracks, without damaging them. Asia NDE supplies ETher NDE eddy current tube testing instruments and the SteelCheck flux leakage tube tester across Malaysia and Southeast Asia. We serve oil and gas and petrochemical customers, with calibration and repair support from our Subang Jaya office.

Tube Inspection equipment

What it’s used for

  • Eddy current tube testing of non-ferrous tubes in heat exchangers and condensers.
  • Testing carbon steel and fin fan tubes with magnetic flux leakage.
  • Telling inside (ID) defects from outside (OD) defects and measuring wall loss.
  • Mapping tube sheets and producing reports for shutdown records.

Products in this category

3 products

  • ETi-200

    ETi-200

    Compact multi-frequency, multi-channel portable eddy current flaw detector for tube inspection, with a 7-inch display, removable cartridge and single or dual-probe operation.

  • ETi-300 / ETi-350

    ETi-300 / ETi-350

    End-to-end eddy current tube inspection system for non-ferrous heat exchanger and condenser tubing, with up to 15 hours battery life, IP66 enclosure and mapping-to-reporting software.

  • SteelCheck

    SteelCheck

    Battery operated 3 channel magnetic flux leakage tube tester for carbon steel and fan fin tubes, discriminating OD and ID defects and wall thinning.

Frequently asked questions

How are heat exchanger tubes inspected?

A probe is pushed through each tube from the tube sheet and pulled back at a steady speed while the instrument records the signal. Eddy current testing is used for non-ferrous tubes. Magnetic flux leakage is used for carbon steel tubes, including fin fan tubes. The results show wall loss, pitting and cracks for each tube.

Which method should I use for fin fan tubes?

Carbon steel fin fan tubes are usually tested with magnetic flux leakage (MFL), as on the SteelCheck. Unlike remote field eddy current, it is not affected by the external aluminium fins, and it can tell inside defects from outside defects.

Contact

Talk to our NDT equipment team

Ask us about prices, stock, choosing the right equipment, calibration and repairs.

WhatsApp us on +60 16-217 1932 — the quickest way to reach us. We're open 9am–5pm; visits are by appointment.

Company

Asia NDE Sdn. Bhd.No. 60, TS 6/4, Subang Industrial Park,47510 Subang Jaya, Selangor Darul Ehsan, Malaysia.

GPS N 03°02.409', E101°35.926